Customized Solutions

The ACS800-U7 is built in a robust cabinet designed for heavy-duty industrial applications with power ratings from 75 to 600 Hp.

The ACS800-U7 offers a wide variety of standardized configurations to adapt to different application requirements, from line contactor to prevention of unexpected motor start.

If your application requires more, ABB's application engineering services can add special features to the standard product such as an additional cabinet for customer specific devices to ensure exact suitability for the application.

Extensive Range of Features

The ACS800-U7 has an extensive range of built in features and options. Typical option choices include extended I/O and fieldbus options, line contactor, EMC filtering, common mode filtering and du/dt (voltage rise) filtering, all mountable within the single cabinet.

Main Standard Features

  • Compact design
  • UL Type 1 protection class
  • Built in harmonic filtering AC choke
  • Common mode filters for motor protection
  • Line fuse disconnect switch
  • Extensive, programmable I/O
  • Inputs galvanicallly isolated
  • Long lifetime cooling fan and capacitors
  • 3 I/O and fieldbus extension slots inside
  • Alphanumeric multilingual control panel with start-up assistant feature
  • Top entry and exit of cables

Back to Top


Ratings and Dimensions

  • Supply Voltages 380-500
  • Supply Voltages 525-600

3-phase supply voltage 380, 400, 415, 460, 480, 500.
The power ratings are valid at nominal voltage, 480Vac 60Hz

Type Designation Frame
Size
Input
A
Imax
A
I2N
A
PN
Hp
I2HD
A
PHD
Hp
Noise Level
dBA
Air Flow
ft3/min
Head Dissipation BTU/hr Click for Quote
ACS800-U7-0100-5R61211641241009675632386610
ACS800-U7-0120-5R6155202157125124100632387890
ACS800-U7-0140-5R6180282180150156125632389600
ACS800-U7-0170-5R71913261921501621257131810100
ACS800-U7-0210-5R72433842402001921507131812900
ACS800-U7-0260-5R72914322862002241507171815300
ACS800-U7-0270-5R82994803162502402007271815350
ACS800-U7-0300-5R83365683613003022507271818050
ACS800-U7-0320-5R84245884353503402507271823250
ACS800-U7-0400-5R84985885104003703007271826650
ACS800-U7-0440-5R85438405454504904007271825950
ACS800-U7-0490-5R8590840590500515(1)4507271827600
ACS800-U7-0550-5R86691017670550590(1)5007271831100
ACS800-U7-0610-5R87021017704600590(1)5007271833000

3-phase supply voltage 525, 575, 600.
The power ratings are valid at nominal voltage, 575Vac 60Hz

Type Designation Frame
Size
Input
A
Imax
A
I2N
A
PN
Hp
I2HD
A
PHD
Hp
Noise Level
dBA
Air Flow
ft3/min
Head Dissipation BTU/hr Click for Quote
ACS800-U7-0070-7R69510473605450652384200
ACS800-U7-0100-7R612112486756260652385650
ACS800-U7-0120-7R61551721081008675652386700
ACS800-U7-0140-7R712619012512595100713189600
ACS800-U7-0170-7R71562631551501311257131812150
ACS800-U7-0210-7R7191294165/195(2)150/200(2)1471507131814550
ACS800-U7-0260-7R7217326175/212(2)150/200(2)1631507131816400
ACS800-U7-0320-7R82984332903002162007271821050
ACS800-U7-0400-7R83335483443502742507271822750
ACS800-U7-0440-7R83776563874003283507271825300
ACS800-U7-0490-7R84237754264503874007271828900
ACS800-U7-0550-7R84688534825004264507271828350
ACS800-U7-0610-7R85339645375004825007271833300

Options for ASC800-U7


Product Catalog

For a complete list of options and details, view the product catalog:
pdfACS800 Single Drives Catalog


  • Analog and digital I/O extension modules
  • Brake chopper and resistor
  • Cabinet heater
  • Customer terminal block
  • Ground fault monitoring for ungrounded network
  • EMC filter for 1st environment, restricted distribution according to EN 61800-3
  • EMC filter for 2nd environment, unrestricted distribution according to EN 61800-3
  • Fieldbus modules
  • UL Type 1 Filtered and UL Type 12 enclosure classes
  • Line contactor with emergency stop push button
  • Output for aux fan motor
  • Pulse encoder interface module
  • Prevention of unexpected start up of motor
  • 1 or 2 thermistor relays
  • 3, 5 or 8 PT100 relays
  • Resolver Interface (Limited SW Support)

Dimensions

Frame Size Width (in) UL Type 1
Height (in)
UL Type 12
Height (in)
Depth (in) Weight (lbs)
R616.983.991.125.4661.40
R732.783.991.125.4881.80
R832.783.991.125.41102.31

Notes

(1)50% overload is allowed if ambient temperature is 30ºC or less, overload is limited to 40% at 40ºC

(2)The higher rating is available when ouput fequency is above 41Hz.

Imax current available for 10 seconds at start.
I2N continuous base current at 40º C (104º F).
Overload cycle 110% I2N for 1 minute / 5 minutes allowed.
I2HD continuous base current at 40º C (104º F).
Overload cycle 150% I2HD for 1 minute / 5 minutes allowed.


Current ratings do not change with different supply voltages.

Horsepower ratings are based on NEMA motor ratings for typical 4-pole motors (1800 rpm). Check motor nameplate current for compatibility.

Back to Top